How engineering works.

Clear explanations with interactive examples. Diagrams simplify reality and do not control any real equipment.

Corrosion calculations

Compare APK corrosion calculations under annexes 1, 2 and 3. Use E units for applicable body components and percentage thickness loss for applicable chassis members. A separate model shows hypothetical thickness loss over time.

INTERACTIVE EXAMPLESIMULATION

Who communicates with whom?

Select annex 1 for unitary bodies, annex 2 for chassis members covered by article 15, or annex 3 for its applicable other components. First check construction, component and exceptions. Material thickness over time is a separate model, not an APK annex.

Voltage and waveform

The E methods in annexes 1 and 3 concern material lost through its full thickness. Annex 2 assesses loss of original metal thickness. Visible rust layers, thickness-loss percentages and E scores are different quantities. Measure remaining base metal and assess relevant local damage.

Measuring with an oscilloscope

E calculations use the highest applicable percentage. Compare perimeter and length for members; area and edge length for panels. An annex 1 wheel housing requires additional attachment-side assessment. Annex 3 treats a wheel housing as an article 20 panel graded 2E. Attachments require estimated strength loss in the applicable region. Annex 2 uses measured remaining thickness rather than the E formula.

The principle

E = damage extent / 100 × applicable grade, compared numerically against 2E. Annex 2: thickness loss = (original thickness − remaining thickness) / original thickness × 100%. Limits are 30% for crossmembers and 20% for the other listed chassis structures. Article 15 determines application and exceptions, including original sheet thickness no more than 2 mm for the specified members/axle attachments and members solely supporting the load floor. The separate time model uses a user-supplied constant loss rate.

An example

For a sill with 20% perimeter damage and 30% length damage, the governing 30% gives 1.8E under annex 1 at grade 6E. The corresponding annex 3 sill grade is 4E, giving 1.2E. A longitudinal member originally 5.0 mm thick with 4.0 mm remaining has lost 20%; an applicable crossmember reduced from 5.0 to 3.5 mm has lost 30%. These results check only the selected calculation, not every inspection requirement.

Important

Select the annex by construction and applicable articles, not just the component name. A main member of a fully load-bearing chassis does not automatically follow the annex 3 E list: check annex 2 and article 15 first. Repairs, continuous section damage, local pitting, special requirements and strength require further assessment. The time model predicts no safe remaining life. This calculator does not issue complete APK approval.

Technical source / documentation ↗